NAME | LIBRARY | SYNOPSIS | DESCRIPTION | RETURN VALUE | ERRORS | STANDARDS | HISTORY | NOTES | SEE ALSO | COLOPHON |
|
|
s390_runtime_instr(2) System Calls Manual s390_runtime_instr(2)
s390_runtime_instr - enable/disable s390 CPU run-time instrumentation
Standard C library (libc, -lc)
#include <asm/runtime_instr.h> /* Definition of S390_* constants */ #include <sys/syscall.h> /* Definition of SYS_* constants */ #include <unistd.h> int syscall(SYS_s390_runtime_instr, int command, int signum); Note: glibc provides no wrapper for s390_runtime_instr(), necessitating the use of syscall(2).
The s390_runtime_instr() system call starts or stops CPU run-time instrumentation for the calling thread. The command argument controls whether run-time instrumentation is started (S390_RUNTIME_INSTR_START, 1) or stopped (S390_RUNTIME_INSTR_STOP, 2) for the calling thread. The signum argument specifies the number of a real-time signal. This argument was used to specify a signal number that should be delivered to the thread if the run-time instrumentation buffer was full or if the run-time-instrumentation-halted interrupt had occurred. This feature was never used, and in Linux 4.4 support for this feature was removed; thus, in current kernels, this argument is ignored.
On success, s390_runtime_instr() returns 0 and enables the thread for run-time instrumentation by assigning the thread a default run-time instrumentation control block. The caller can then read and modify the control block and start the run-time instrumentation. On error, -1 is returned and errno is set to indicate the error.
EINVAL The value specified in command is not a valid command. EINVAL The value specified in signum is not a real-time signal number. From Linux 4.4 onwards, the signum argument has no effect, so that an invalid signal number will not result in an error. ENOMEM Allocating memory for the run-time instrumentation control block failed. EOPNOTSUPP The run-time instrumentation facility is not available.
Linux on s390.
Linux 3.7. System z EC12.
The asm/runtime_instr.h header file is available since Linux 4.16. Starting with Linux 4.4, support for signalling was removed, as was the check whether signum is a valid real-time signal. For backwards compatibility with older kernels, it is recommended to pass a valid real-time signal number in signum and install a handler for that signal.
syscall(2), signal(7)
This page is part of the man-pages (Linux kernel and C library
user-space interface documentation) project. Information about
the project can be found at
⟨https://www.kernel.org/doc/man-pages/⟩. If you have a bug report
for this manual page, see
⟨https://git.kernel.org/pub/scm/docs/man-pages/man-pages.git/tree/CONTRIBUTING⟩.
This page was obtained from the tarball man-pages-6.9.1.tar.gz
fetched from
⟨https://mirrors.edge.kernel.org/pub/linux/docs/man-pages/⟩ on
2024-06-26. If you discover any rendering problems in this HTML
version of the page, or you believe there is a better or more up-
to-date source for the page, or you have corrections or
improvements to the information in this COLOPHON (which is not
part of the original manual page), send a mail to
man-pages@man7.org
Linux man-pages 6.9.1 2024-05-02 s390_runtime_instr(2)
Pages that refer to this page: syscalls(2)